Current Issue

View Larger Image

Past Issues Free Subscriptions
Sponsored
Keywords



New Products

Related to Novel MS Systems Expedite Workflow

    • Mass Spec Sample Prep
    • PerkinElmer
    • The AxION® Direct Sample Analysis (DSA) system reduces the number of sample preparation steps in addition to the need for front-end gas or liquid chromatography separation, as samples can be directly introduced to a mass spectrometer. With the
    • Time-of-Flight Mass Spectrometers
    • Waters
    • Equipped with StepWave™’s off-axis ion source technology, Xevo G2-S® QTof and Xevo G2-S Tof mass spectrometers are up to 20x more sensitive than earlier-generation instruments. StepWave ion optics technology transfers ions from the ion source
    • Mass Spectrometers
    • AB Sciex
    • The Triple Quad™ 6500 and QTRAP® 6500 systems are next-generation mass spectrometers that can deliver up to a 10x increase in sensitivity. The 6500 series features multicomponent IonDrive™ technology that can increase the generation, transmiss
    • TOF Mass Spec
    • AB Sciex
    • TripleTOF 4600 system is designed for a variety of applications, including high-throughput discovery proteomics and routine and comprehensive analysis of drug metabolites in early ADME. The system is designed as a workhorse instrument, combining ra
    • MALDI TOF/TOF Mass Spec
    • Bruker
    • The ultrafleXtreme™ MALDI TOF/TOF system features Top-Down T 3 -Sequencing for revealing terminal modifications, post-translational modifications, and sequence impurities. High-resolution intact biomolecule analysis is possible on the ultrafleXtrem
    • Bio Standards
    • Waters
    • Seven new standards for peptides, proteins, and glycans are now available. These include the Cytochrome C Digestion standard for peptides, the Acquity UPLC® BEH200 SEC protein standard mix for proteins, and the Glycan Performance Test standard
    • Interfering Protein Removal
    • ANP Technologies
    • The NIDS® NPX4000 interfering protein removal/extraction kit enables the analyst to prepare coated nanoparticles for scavenging of interfering proteins prior to analysis. Interfering substances such as endogenous binding proteins, free drug mo
    • Mass Spec Pipette Tips
    • Thermo Fisher Scientific
    • The MSIA™ pipette tips can be used to enrich target proteins/peptides for downstream mass spectrometric quantification, helping to accelerate biomarker research. Users can streamline the immunoaffinity sample preparation process and LC/MS method wi
    • MS Data Analysis System
    • Genedata
    • Expressionist MSX® analyzes proteomics and metabolomics data for a variety of applications directly from the instrument. It can be downloaded in a Windows-executable file and can be set up in minutes. The algorithms in Expressionist MSX can re
    • PDMS Chip Connection Interface
    • Dolomite Centre
    • The PDMS Chip Interface allows users to create reliable and leak-free fluidic connections to PDMS chips. The interface allows chips to be used outside the lab, which can widen applications for PDMS chips beyond research as well as the opportunity f
    • Light-Scattering Detectors
    • Agilent Technologies
    • The 1290 Infinity and 1260 Infinity evaporative light-scattering detectors are suited for the analysis of non- and semi-volatile compounds in pharmaceutical, drug discovery, QA/QC, and other forms of analysis. Both can screen pharmaceutical compoun
    • Peptoid Libraries
    • RayBiotech
    • Peptoid library services that can help users select high-affinity peptide mimetics that can bind to the target protein of their choice are now available. Peptoid libraries are available in both bead-based and array formats. Additional services incl
    • His-Tagged Protein Purification
    • Roche
    • The cOmplete His-Tag purification resin is a high-capacity immobilized metal affinity chromatography matrix for convenient single-step purification of His-tagged protein. Compatibility with large amounts of EDTA and DTT allows optimization of buffe
    • Sample Prep/LC System
    • Thermo Fisher Scientific
    • The Prelude SPLC sample preparation and liquid chromatography system was developed to make analysis of target compounds in complex biological matrices routine for clinical research and forensic toxicology laboratories. It is designed to enhance LC-
    • MS Syringe Filter
    • Pall Life Sciences
    • Acrodisc® MS is a syringe filter certified for low extractables in high-performance liquid chromatography/mass spectrometry applications. The 13 mm size is designed for small sample analysis and low extractable levels. MS syringe filters can r
    • Mass Spectrometers
    • Bruker
    • The EVOQ and the EVOQ Elite mass spectrometers feature vacuum-insulated probe-heated electrospray ionization technology, an active exhaust atmospheric pressure ionization source with an orifice vacuum interface, an interlaced quadrupole dual funnel
    • Antibody Arrays
    • R&D Systems
    • With Proteome Profiler Antibody Arrays, instead of performing multiple Western blots, users can start their experiments by profiling their lysates for up to 59 phospho-proteins in a single sample. Proteome Profiler Antibody Arrays can reveal relati
  • Page 1 of 1 (17 items) 1 

GEN Poll

More » Poll Results » Archive »

Genome Sequencing and Patient Autonomy

Do you think ACMG’s recent recommendations for reporting incidental clinical sequencing results undermine patient autonomy?

Suggest a Poll